The resulting materials were hydrophobic. Hemocompatibility testing under static conditions revealed no effect on hemolysis following the addition of arginine and the prolongation of the prothrombin time with the increased addition of arginine, thus exerting an influence on the extrinsic and common pathway of coagulation activation. The results of the dynamic hemocompatibility assessment revealed that the numbers of blood cells and platelets were not affected significantly by the various electrospun samples during incubation. The TAT, β-thromboglobulin and SC5-b9 concentrations were characterized by a moderate increase in the PCL group compared to those of the control group. The presence of arginine resulted in a decrease in the investigated hemocompatibility markers. The PMN elastase levels were comparable with respect to all the groups.We report detection of cervical pre-cancer through their low coherence images by applying two dimensional multifractal detrended fluctuation analysis. Low coherent backscattered images of pre-cancerous cervical tissue sections were captured using a common path interferometric setup. The captured images contain both depth and lateral information of the spatial variation in refractive index (RI) occurring with progression of cervical pre-cancer. A two-dimensional multifractal detrended fluctuation analysis (2D MFDFA) was applied on these low coherent images to study the variations occurring in their fractal nature. Long-range correlations were observed in the RI fluctuations and the strength of multifractality was found to be stronger for higher grades of cervical pre-cancer. A combination of derived multifractal parameters, namely, the generalized Hurst exponent and width of singularity spectrum showed clear differences among the different grades of pre-cancers. Normal, CIN-I and CIN-II were clearly discriminated by application of support vector machine (SVM) using radial Bessel function (RBF) kernel. The specificities and sensitivities between normal and CIN-I, CIN-I and CIN-II and normal and CIN-II were found to be 94%, 88% and 93%, 96% and 98%, 100% respectively.
The 2017 PhysioNet/CinC Challenge focused on automatic classification of atrial fibrillation (AF) in short ECGs. This study aimed to evaluate the use of the data and results from the challenge for detection of AF in longer ECGs, taken from three other PhysioNet datasets.
The used data-driven models were based on features extracted from ECG recordings, calculated according to three solutions from the challenge. A Random Forest classifier was trained with the data from the challenge. The performance was evaluated on all non-overlapping 30 s segments in all recordings from three MIT-BIH datasets. Fifty-six models were trained using different feature sets, both before and after applying three feature reduction techniques.
Based on rhythm annotations, the AF proportion was 0.00 in the MIT-BIH Normal Sinus Rhythm (N = 46083 segments), 0.10 in the MIT-BIH Arrhythmia (N = 2880), and 0.41 in the MIT-BIH Atrial Fibrillation (N = 28104) dataset. For the best performing model, the corresponding detected proportionswhile preserving the classification performance, which can be important when building low-complexity AF classifiers on ECG devices with constrained computational and energy resources.
Magnetic resonance cine imaging is the accepted standard for cardiac functional assessment. Left ventricular (LV) segmentation plays a key role in volumetric functional quantification of the heart. Conventional manual analysis is time-consuming and observer-dependent. Automated segmentation approaches are needed to improve the clinical workflow of cardiac functional quantification. Recently, deep-learning networks have shown promise for efficient LV segmentation.
The routinely used V-Net is a convolutional network that segments images by passing features from encoder to decoder. https://www.selleckchem.com/products/cd38-inhibitor-1.html In this study, this method was advanced as DenseV-Net by replacing the convolutional block with a densely connected algorithm and dense calculations to alleviate the vanishing-gradient problem, prevent exploding gradients, and to strengthen feature propagation. Thirty patients were scanned with a 3 Tesla MR imager. ECG-free, free-breathing, real-time cines were acquired with a balanced steady-state free precession technique. Linea state-of-art neural network methods V-Net, UNet, and FCN.
The proposed DenseV-Net method outperforms the classic convolutional networks V-Net, UNet, and FCN in automated LV segmentation, providing a novel way for efficient heart functional quantification and the diagnosis of cardiac diseases using cine MRI.
The proposed DenseV-Net method outperforms the classic convolutional networks V-Net, UNet, and FCN in automated LV segmentation, providing a novel way for efficient heart functional quantification and the diagnosis of cardiac diseases using cine MRI.The goal of this paper was the comparison of radiation dose and imaging quality before and after the Clarity IQ technology installation in a Philips AlluraXper FD20/20 angiography system using a Channelized Hotelling Observer model (CHO). The core characteristics of the Allura Clarity IQ technology are its real-time noise reduction algorithms (NRT) combined with state-of-the-art hardware; this technology allows to implement acquisition protocols able to significantly reduce patient entrance dose. To measure the system performances in terms of image quality we used a contrast detail phantom in a clinical scatter condition. A Leeds TO10 phantom has been imaged between two 10 cm thick homogeneous solid water slabs. Fluoroscopy images were acquired using a cerebral protocol at 3 dose levels (low, medium and high) with a field- of view (FOV) of 31 cm. Cineangiography images were acquired using a cerebral protocol at 2 fps. Thus, 4 acquisitions were obtained for the conventional technology and 4 acquisitions were taken after the Clarity IQ upgrade, for a total of 8 different image sets. A validated 40 Gabor channels CHO with an internal noise model compared the image sets. Human observers' studies were carried out to tune the internal noise parameter. We showed that the CHO did not detect any significant difference between any of the image sets acquired using the two technologies. Consequently, this x-ray imaging technology provides a non-inferior image quality with an average patient dose reduction of 57% and 28% respectively in cineangiography and fluoroscopy. The Clarity IQ installation has certainly allowed a considerable improvement in patient and staff safety, while maintaining the same image quality.